Experiment metadata

Global metadata table

key

description

ARTICLE_DOI

DOI of the of the original publication of the experimental data

DATA_DOI

DOI of the dataset deposition with raw NMR data

DATA_REF

Reference to deposited dataset

TEMPERATURE

Temperature (K) of the experiment

MEMBRANE_COMPOSITION

Dictionary of molar fractions of membrane phase

SOLUTION_COMPOSITION

Dictionary of ion concentrations in the system

ADDITIONAL_MOLECULES

Dictionary of molecules which are not in the databank

TOTAL_HYDRATION

Total hydration of the system (water mass %)

PH

pH of the system

PH_METHOD

Method of pH setting or measurement (buffer / measurement)

REAGENT_SOURCES

Description of lipid reagents. Source, purity, etc.

SAMPLE_PROTOCOL

Protocol for sample preparation (in free format, references are welcome).

NMR specific metadata

key

description

T_RF_HEATING

Correction of the temperature according to RF heating

INSTRUMENT

Instrument name (including field)

METHOD

Method of OP measurement “abbr1:abbr2” (see detailed explaining below)

SIGN_MEASURED

NONE or S-DROSS

DETAILS

Description of NMR experiment type

X-ray specific metadata

key

description

SOURCE

Source name

LAMBDA

Source wavelength or range

QRANGE

Scattering detection range (Q-range)

DETECTOR

Detector type

DISTANCE

Distance to detector (m)

DATATYPE

Data type (batch or SEC)

EXPOSURE

Exposure time per frame (s)

FRAMES

Number of frames

SAMPLE_TYPE

‘MLV’, ‘SUV’, ‘GUV’, ‘OS’ (oriented sample), ‘BIC’

General fields

  1. ARTICLE_DOI
    DOI of the original publication where the experimental data originates.

  2. DATA_DOI
    DOI of the dataset deposition with raw NMR data (e.g., nmrXive).

  3. DATA_REF If the dataset doesn’t have DOI, we engage to add some persistent identifier or even URL if the first doesn’t exist.

  4. TEMPERATURE
    Temperature (K) of the experiment. For NMR experiment, if NMR:T_RF_HEATING is ‘unknown’ (or not given), the reported temperature from the probe is settet here. Otherwise, please insert RF-corrected temperature.

  5. MEMBRANE_COMPOSITION
    Dictionary of molar fractions of bilayer components. For example:

MEMBRANE_COMPOSITION:
  POPC: 0.93
  CHOL: 0.07

All the molecules should be registered in the molecular inventory in the membrane subfolder.

  1. SOLUTION_COMPOSITION
    Dictionary of solution composition of the system (mass %), main solvent is not listed:

SOLUTION_COMPOSITION:
  SOD: 0.5
  CLA: 0.24
  GLUCOSE: 0.1

All the molecules should be registered in the molecular inventory in the solution subfolder. Do not provide whole salts! Only separated ions. Remember that the counterions of charged lipids are also part of the solution.

  1. ADDITIONAL_MOLECULES Dictionary of additional molecules in the format:

ADDITIONAL_MOLECULES:
    TFA: trifluoroacetic acid, 0.1%
    DMSO: dimethylsulfoxide, 0.1%
    DSS: sodium trimethylsilylpropanesulfonate, 0.01%
    EDTA: ethylenediaminetetraacetic acid, 0.1 mM

we can use INCHI-key, CAS number or just IUPAC name. If molecule is important for the composition, it should get the metadata inside the databank and be mentioned under SOLUTION_COMPOSITION instead.

  1. TOTAL_HYDRATION
    Mass % of water in the sample. For NMR experiment, it is better if measured by 1H MAS NMR.

  2. PH
    pH of the system (number or UNKNOWN)

  3. PH_METHOD
    How the pH value is got: measured by pH electrode or indicator paper, measured by NMR, set by buffer.

  4. REAGENT_SOURCES
    Which reagents are used for lipids – should be specified for every lipid.

  5. SAMPLE_PROTOCOL Protocol of liposome (or OS) preparation. A description of the preparation steps and conditions used to obtain the sample, such as lipid composition, hydration method, extrusion, alignment procedures, and any buffers used. For NMR sample, it is important to mention how the targeted hydration level is reached: lyophilised powder is hydrated, liposome suspension is dehydrated, or liposome suspension is ultracentrifugated to get lipid-rich phase.

NMR-specific fields

All the following fields are subfields of NMR: block.

  1. INSTRUMENT
    Name of the instrument and field strength.

  2. METHOD
    A field identifying the NMR method used (string formed as METHOD:SUBMETHOD, e.g., “2H:QE”).

    • Variants for METHOD: “2H”, “CDLF”, “PDLF”
      Two main methods are 2H-NMR and 1H-13C SLF (separate local field) NMR experiments which can be either CDLF (Carbon-detected local field) or PDLF (Proton-DLF).

    • Sub-Method for “2H”: “SP” | “QE” | “see_comments”
      For 2H NMR, the submethod used is either “single pulse” or “quadrupolar echo”.

    • Sub-Method for “CDLF”: “REDOR” | “DIPSHIFT” | “recDIPSHIFT” | “see_comments”
      For CDLF method, the variants could be Rotational-Echo Double-Resonance (REDOR), Dipolar-Coupling chemical shift correlation (DIPSHIFT), or recoupled DIPSHIFT (recDIPSHIFT).

    • Sub-Method for “PDLF”: “DROSS” | “R18_1^7” (or other numbers characterizing R-type sequence) | “see_comments”
      For PDLF method, subvariants could use dipolar recoupling on-axis with scaling and shape preservation (DROSS), or R-type recoupling (recoupling using symmetry-based pulse sequences)

  3. SIGN_MEASURED
    Method name (e.g. S-DROSS) if order parameter sign was measured, NONE otherwise.

  4. T_RF_HEATING
    How RF heating is dealt (UNKNOWN / measured / guessed)

  5. DETAILS
    Links to the pulse sequence, corresponding paper and precise parameters if important. Obligatory explanation if NMR:METHOD uses “see_comments” for SUBMETHOD.

Scattering-specific fields

All the following fields are subfields of XRAY: block.

  1. SOURCE X-ray source description. Name of the core facilities or instrument name if laboratory source was used. Name of beamline and source if synchrotron data (e.g. EMBL P12, PETRA III).

  2. LAMBDA Source wavelength or range. Wavelength (and/or range) of the X-ray beam used, with units (e.g., Ångstroms).

  3. QRANGE Scattering detection range (Q-range). The accessible scattering vector range, typically given in 1/Å.

  4. DETECTOR Detector type (e.g., CCD camera, PILATUS, or other detector model).

  5. DISTANCE Distance to detector (m). The separation between the sample and the detector, in meters.

  6. DATATYPE Measurement data type. Batch mode or size-exclusion chromatography (SEC) mode.

  7. EXPOSURE Exposure time per frame. The total data acquisition time per measurement frame, usually given in seconds.

  8. FRAMES Number of frames collected for dataset.

  9. SAMPLE_TYPE ‘MLV’, ‘SUV’, ‘GUV’, ‘OS’ (oriented sample), ‘BIC’. The type of sample used, with definitions: MLV (multilamellar vesicles), SUV (small unilamellar vesicles), GUV (giant unilamellar vesicles), OS (oriented sample), BIC (bicelles).